ProductsThe production site control and standardized assembly line are designed according to European standards. The products are divided into 8 series and 115 models.
-
Service SupportThe service system of Comps company spreads all over the country, we have the strongest technical force and can make the fastest response to the actual needs of users.
-
NewsInnovation is the life of an enterprise. Comps pursues sustainable operation. Every year, 10% of sales are invested in joint technology research and development with professional colleges.
-
About UsFounded in June 2004, Comps Compressor Co., Ltd. is a high-tech enterprise integrating R&D, manufacturing and marketing, and enjoys a high reputation in the industry.
-
ApplicationThe service system of Comps company spreads all over the country, we have the strongest technical force and can make the fastest response to the actual needs of users.
How to deal with the solenoid valve failure on the Best Variable Speed electric driven screw air compressor SPM210 components
The failure of the solenoid valve on the Best Variable Speed electric driven screw air compressor SPM210 components will directly affect the action of the switching valve and the regulating valve. For common solenoid valve failures, you can troubleshoot and solve them from the following aspects:
1. The solenoid valve terminal of the Best Variable Speed electric driven screw air compressor SPM210 is loose or the thread end falls off, and the solenoid valve cannot be connected to the current. At this time, the thread end can be tightened to solve the problem.2. If the solenoid valve coil of the Best Variable Speed electric driven screw air compressor SPM210 is burnt out, the wiring of the solenoid valve can be removed and measured with a professional instrument. The reason for the burnout of the coil is that the coil is damp, which leads to a decrease in insulation performance and magnetic flux leakage, and the current in the coil is too large. Therefore, when using the solenoid valve of the Best Variable Speed electric driven screw air compressor SPM210 components, avoid rainwater from entering. In addition, the spring of the solenoid valve is too hard, the reaction force is too large, the number of coil turns is too small, and the suction force is not enough to cause the coil to burn.
3. The solenoid valve of the Best Variable Speed electric driven screw air compressor SPM210 is stuck. The cooperation gap between the slide valve sleeve and the valve core of the solenoid valve is very small, and they are usually installed in a single piece. When mechanical impurities are brought in or there is too little lubricating oil, it is easy to get stuck. If the solenoid valve is stuck, the steel wire can be poked through the small hole on the solenoid valve to make it bounce back. In addition, it is best to remove the solenoid valve of the Best Variable Speed electric driven screw air compressor SPM210 components, take out the valve core and the valve core sleeve for cleaning, so that the valve core can move sensitively in the valve sleeve.