ProductsThe production site control and standardized assembly line are designed according to European standards. The products are divided into 8 series and 115 models.
-
Service SupportComps's service system covers all major and medium-sized cities across the country. Not only does the company have a complete service team, but it is also committed to developing and training professional dealers and service providers across the country to form a huge service network, ensuring that more than 80% of the country's cities and surrounding areas; service personnel arrive at the scene within 8 hours after receiving the notice.
-
NewsInnovation is the life of an enterprise. Comps pursues sustainable operation. Every year, 10% of sales are invested in joint technology research and development with professional colleges.
-
About UsShijiazhuang Comps Compressor Co., Ltd. was established in June 2004 with a registered capital of 35 million yuan. The company is located at 172 Nanche Road, Luancheng District, Shijiazhuang, Hebei Province. It is a high-tech enterprise integrating research and development, manufacturing, and marketing, and enjoys a high reputation in the industry. In 2017, Kangpu Compressor Co., Ltd. built a new factory area with an investment of 160 million yuan, covering a total area of 158 acres. The company's production and manufacturing center covers an area of 68 acres.
-
ApplicationThe service system of Comps company spreads all over the country, we have technical force and can make response to the actual needs of users.

What are the reasons for insufficient exhaust?
1) The relief valve shall be unloaded when it should not be unloaded. Check whether each relief valve is stuck and deflates all the time.
2) The air filter is blocked, resulting in less air intake. Remove the air filter element and conduct a short test run to see whether the pressure has increased (for units without safety filter element, pay attention to ensure that sundries do not enter the machine head)
3) The speed decreases. (the shaft is broken, the belt loses rotation and slips, the rated frequency of the frequency converter is low, and the throttle of the diesel engine is not in place)
4) Tolerance adjustment moves in advance.
5) The intake valve is stuck and cannot be opened or cannot be fully opened.
6) The oil is blocked.
7) Insufficient false gas volume: the gas consumption of subsequent equipment increases, or the pipeline leaks. There may be geological ground joints with drilling rig. The treatment method is to check the air compressor to prevent problems in the air compressor, and close the ball valve to see that the rated pressure can be reached. For electrically driven units, check whether the current is consistent with the current under normal conditions under rated pressure, so as to judge whether there is a large change in gas volume.
8) Measure the air volume and eliminate the problem of air compressor.