图片名称

Compus compressor explain why the double - stage compression screw machine nose stuck


Head stuck is a common fault of two-stage compression screw machine, generally because of insufficient lubricating oil, but some need maintenance personnel to check to judge, the following compus compressor specifically explains the cause of two-stage compression screw machine head stuck.

1, long-term shutdown, the head of the internal oil is insufficient, resulting in instant lack of oil, resulting in stuck, so the long-term shutdown of the equipment to add enough oil to the head, the machine again.

2, oil supply is insufficient, including lubricating oil replacement or addition is not timely, or oil road blockage, leakage, resulting in lack of oil stuck in the nose.

3, bearing aging leads to serious wear. The specific detection of bearing wear can be carried out when the bearing is not removed, and the needle or ball roller in the lower side of the bearing can be moved. If it can be easily moved, it needs to be replaced. With the passage of air compressor running time, the host bearing will wear, resulting in the increase of axial and radial movement of the screw, the change will make the gap between the screw and the screw, the screw and the host housing and the front and rear end changes.

Shijiazhuang Compus Compressor Co., Ltd. is a high-tech enterprise engaged in the research and development, production and sales of air compressors. Its main products are oil-free mobile, drilling air compressor, two-stage compression screw machine, centrifugal air compressor, high pressure mobile machine and so on. The company with strong scientific research and technical strength, focus on research and development and manufacturing of air compressor, in the industry enjoys a high reputation, welcome to inquire.